ADVANTAGES OF ARTERIOGRAPH
Medical and Efficient ➙ PUB
-
Improved patient care
-
Detection of subclinical atherosclerosis
-
Improved basis for decision-making on therapies
Precise and reproducible
-
Clinically and invasively validated ➙ PUB
-
Over 150 studies in each subject area ➙ PUB
User-independent
-
Simple and fully automatic system
-
like a normal blood pressure monitor
Quick and easy to understand ➙ PUB
-
Measurement of 17 parameters in 2 minutes
-
Clear findings for doctor and patient
Attractive Profit ➙ INCOME
-
GOÄ 648a: Measurement of central arterial pressure
-
81.11 Euro with the 2.3-fold rate
MEASUREMENT PARAMETER
Peripheral Brachial Blood Pressure
-
Systolic blood pressure (SBP)
-
Diastolic blood pressure (DBP)
-
Mean Arterial Pressure (MAP)
-
Pulse pressure (PP)
-
Heart rate (HR)
Central Blood Pressure ➙ PUB
-
Aortal central systolic blood pressure (SBPao)
-
Aortal central pulse pressure (PPao)
Augmentationsindex ➙ PUB
-
Aortal central augmentation index (AIXao)
-
Brachial augmentationindex (AIXbr)
Pule Wave Velocity ➙ PUB
-
Aortal pulse wave velocity (PWVao)
-
Return time of the aortal pulse wave (RTao)
-
Ejection time of the left ventricle (ED)
-
Standard deviation of the PWV (SD)
-
Determination of arterial age
Diastolic Results ➙ PUB
-
Diastolic Reflection Range (DRA)
-
Systolic Area Index (SAI)
-
Diastolic range index (DAI)
Ankle Brachial Index
-
Ankle Brachial Index (ABI)
ARTERIOGRAPH-SOFTWARE
TECHNICAL PARAMETERS
-
Power supply: 4 AA long-life batteries or rechargeable batteries of type AA
-
Protection against electric shock: Internal power supply by batteries
-
Electric shock: Application part type BF
Electricity
-
Display: Liquid crystal display (LCD)
-
Data storage: EEPROM
-
Data transmission: Bluetooth 2.0
Hardware
-
Operating temperature: 10°c - 40°c
-
Dimensions: 116x94x47mm
-
Weight (including batteries): 250g
Operation and Dimensions
-
Method of BP measurement: Oscillometric
-
Sampling frequency: 200 Hz
-
Measuring range: 30-280 mmHg
-
Static accuracy: 3mmHg or 2% of measured value (stability: 2 years)
Measuremethod
-
Pressure sensor: Piezoresistive sensor
-
Pressure generation: Motorized Cuff
Pressure
-
Maximum cuff pressure: 280 mmHg
-
Air release: Automatic, stepwise
Safety
DOWNLOAD & SUPPORT
Here you will find the latest version of the Arteriograph software. You can also download the operating instructions, the patient flyer or the Arteriograph brochure and find out about arterial stiffness!
Check the FAQs, ask us a question or report a problem using the Troubleshooting Form. We will contact you within 24 hours.